Product Details
Place of Origin: China
Brand Name: Calin
Certification: CE/SABS/IEC
Model Number: CA168
Payment & Shipping Terms
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: Carton
Delivery Time: 30 days
Payment Terms: Western Union, Paypal,T/T, L/C
Supply Ability: 70,000pcs per month
Name: |
Smart Prepayment Meter |
Standard: |
DLMS/COSEM |
Communication: |
PLC/RF/GPRS/3G/4G LTE |
Nominal Voltage Un: |
220/230/240 V |
Limited Voltage: |
70%~120%Un |
Storage Temperature: |
40℃ To+85℃ |
Name: |
Smart Prepayment Meter |
Standard: |
DLMS/COSEM |
Communication: |
PLC/RF/GPRS/3G/4G LTE |
Nominal Voltage Un: |
220/230/240 V |
Limited Voltage: |
70%~120%Un |
Storage Temperature: |
40℃ To+85℃ |
Single Phase GSM DLMS Prepaid Electricity Meters Smart Prepayment Meter
Single Phase GSM DLMS Smart Electricity Meter
Single Phase GSM DLMS Smart Electricity Meter CA168
The CA168 is used for a wide rang of smart metering applications.It combines latest 3DES security encryption technology and modular communication unit. The meter is allowing a basic current of 5 Amp while retaining a maximum current of 80 Amp and extended AMR/AMI functional features. It is a compact design in a BS8565 standard housing and maintains the rugged RF immunity withstand of 30V/m and IP54 rating, allowing it to operate in harsh environments.
The meter works with a plug-in modules for DLMS/COSEM compliant data collection and network communications. This modular design enables utility to select from PLC/RF/GPRS/3G and 4G LTE cellular data newworks according to local conditions at low cost. Upgrade and maintenance will also become cost-effective by replacing the modules only instead of the entire meter.
Major Features
Utility benefit
Specifications:
Nominal voltage Un | 220/230/240 V |
Limited voltage | 70%~120%Un |
Nominal frequency fn | 50-60Hz+5% |
Basic current(Ib) | 5-10A |
Maximum current(Imax) | 60-100A |
Starting current(Ist) | 20mA |
Active energy constant | 1000imp/kWh |
Accuracy as Active energy to IEC62053‐21 | Class1.0 |
Power consumption in Voltage circuit | <2W <8VA |
Power consumption in current circuit | <1VA |
Operating temperature | 25℃ to+70℃ |
Storage temperature | 40℃ to+85℃ |
Insulation level | 4kV rms for 1min |
Impulse voltage withstand | 8kV, 1.2/50 μs |
Air discharge | 16kV |
Immunity to HF fields | |
80MHz to 2GHz with load | 10V/m |
100kHz to 1GHz without load | 30V/m |
Fast transient burst test | 4kV |
Meter shell Protection Rate | IP54(IEC60529) |
Insulation System Classification | Protective Class II |