Send Message
Shenzhen Calinmeter Co,.LTD
products
products
Home > products > AMI Solutions > PLC communication AMI solutions corporate luxry villas multi - storey buildings for tenants

PLC communication AMI solutions corporate luxry villas multi - storey buildings for tenants

Product Details

Place of Origin: China

Brand Name: Calin

Certification: IEC

Model Number: Calinpay-S

Payment & Shipping Terms

Minimum Order Quantity: Negotiation

Price: Negotiation

Packaging Details: With meters in carton or in memory card

Delivery Time: 30 days

Payment Terms: Western Union, L/C, T/T, Paypal

Supply Ability: 7,000,000

Get Best Price
Highlight:

ami systems

,

amr system

,

PLC AMI solutions

Standard:
IEC62055-51, IEC 62056-21, DLMS/COSEM
O/S:
Windows
Database:
SQL ORACLE
Operation:
Multi-threaded Concurrent Transaction
Connection Type:
PLC To Concentrator, GPRS To HES
Communication:
Internet, Intranet, LAN / WAN
Standard:
IEC62055-51, IEC 62056-21, DLMS/COSEM
O/S:
Windows
Database:
SQL ORACLE
Operation:
Multi-threaded Concurrent Transaction
Connection Type:
PLC To Concentrator, GPRS To HES
Communication:
Internet, Intranet, LAN / WAN
PLC communication AMI solutions corporate luxry villas multi - storey buildings for tenants

PLC  communication AMI solutions corporate luxry villas multi - storey buildings for tenants

 

Power-line communication (PLC) is a communication protocol that uses electrical wiring to simultaneously carry both data, and Alternating Current (AC) electric power transmission or electric power distribution.
Power-line carrier communication  can be used by utilities for advanced energy management techniques (such as OpenADR and OpenHAN),[15] fraud detection and network management,[16] automatic meter reading (AMR), advanced metering infrastructure, demand side management.[17] load control, and demand response.
In a two-way system, commands can be broadcast out from the master station to end devices (meters) – allowing for reconfiguration of the network, or to obtain readings, or to convey messages, etc. This type of broadcast allows the communication system to simultaneously reach many thousands of devices—all of which are known to have power, and have been previously identified as candidates for load shed. PLC also may be a component of a Smart Grid.

 
 
 

Key Benefit

 

1)     Easy and quick to deploy using existing wires with no need for accessories

2)     Cost-effective and low maintenance solution

3)     Two way communication by IEC standards 

4)     Automatic meter reading and load shedding controls 

5)     Suitable for multi-tenants complexes, staff accommodations, student dorms,etc

6)     Programmable meter reading interval

7)     Programmable power limit and usage limitations

8)     Reduced operational cost and labor cost for meter reading service

 

 

PLC  communication AMI solutions corporate luxry villas multi - storey buildings for tenants 0

AMI electricity meter Specification Datasheet

 

 

Parameter

1 Phase

3 Phase

Nominal voltage

110/120/220/230/240V

Un (40%- 130%)

3x110/120/220/230/240V Un(30%- 135%)

Norminal current

5(60)A

10(100)A

Connection type

Whole current / CTVT connection

Whole current / CTVT connection

Maximum current

80A

100A

Frequency

50Hz

50Hz

Accuracy class 

IEC Class.1

IEC Class.1

Voltage circuit burden

≤1.5W & 1.2VA

≤1.5W & 5VA

Current circuit burden

≤0.2VA

≤0.5VA

Protective class

IP 54 as  IEC 60529

IP54 as  IEC 60529

Insulation class

6kV Class II

6.5kV Class II

Surge immunity

4 kV

4.3kV

Electrostatic discharge

15kV

16kV air discharge

Immunity to HF fields

80MHz to 2GHz@30V/m

80MHz to 2GHz@30V/m

Fast transient burst

4.3kV

4.3kV

Radio interference

As CISPR22

As CISPR22

Battery life without power

10 years

10 years

Dimension

160mmx112mmx71mm

290mmx170mmx85mm

Weight

Approximate 0.7kg

Approximate 3kg